Peptide blend calculator: every component in every draw
In a blended vial every draw contains all components in the same fixed ratio. Enter the milligrams of each component, the water you add and the draw in units: the calculator returns how many micrograms of each component that draw holds, how many such draws the vial gives, and — if you set a target for one component — what the others come along at.
Treat each component of a blend separately: its concentration is its own mg ÷ water mL, and its mcg per U-100 unit is that concentration × 10. GLOW (GHK-Cu 50 + BPC-157 10 + TB-500 10 mg) with 2 mL gives 250, 50 and 50 mcg per unit. The ratio never changes with the draw; only the total does.
On this page
One draw, all partsThe arithmeticExample blendsTargeting one partWater volumeSingle vs blendBlends in VietnamDraws per vialCommon mistakesFrequently asked questionsProportion arithmetic for a pre-mixed vial. Every draw moves all components together; this is not a dosing recommendation.
Why does one draw move every compound at once?
A blend is several peptides freeze-dried together in one vial. Once water is added, they share the same solution, so any volume you take contains each of them in proportion to its mass in the vial. You cannot draw "just the BPC-157" from a GLOW vial. That is the only real difference from single-compound arithmetic, and it is why a blend needs per-component figures rather than one concentration.
The calculator above does exactly that. With the defaults (50 + 10 + 10 mg, 2 mL, 10 units) it reproduces a GLOW vial; set C to 0 for a two-part blend such as Wolverine or CJC-1295 + ipamorelin.
Blends are convenient: one vial, one reconstitution, one measurement. The cost is flexibility, because the manufacturer has fixed the proportions. Understanding that trade-off before buying is the reason to run the numbers here first — if the ratio in a blend does not fit what a protocol needs, single-compound vials are the alternative.
How is the amount of each compound worked out?
- Per-component concentration = that component's mg ÷ water mL. GHK-Cu in GLOW at 2 mL: 50 ÷ 2 = 25 mg/mL.
- Per-component mcg per unit = concentration × 10 (one U-100 unit is 0.01 mL): 25 × 10 = 250 mcg.
- Amount in a draw = mcg per unit × units: 250 × 10 = 2,500 mcg GHK-Cu in 10 units.
- Total concentration = all mg ÷ mL = 70 ÷ 2 = 35 mg/mL — useful as a check, not for measuring any one component.
- Draws per vial = water mL × 100 ÷ units per draw: 200 ÷ 10 = 20.
Check: the per-component amounts across all draws must add back to the vial mass. 20 draws × 2,500 mcg = 50 mg of GHK-Cu. ✓
The ratio between components never depends on the water or the draw: GHK-Cu, BPC-157 and TB-500 stay at 5 : 1 : 1 in every drop of a GLOW solution. That is why the calculator reports the ratio separately — it is a property of the vial you bought, fixed before the first reconstitution.
Worked examples: GLOW, Wolverine and CJC-1295 + ipamorelin
Per-component results for the blends listed in our catalogue (calculated):
| Vial + water | Total concentration | mcg per unit, each part | mcg in 10 units, each part |
|---|---|---|---|
| GLOW 70 mg + 2 mL | 35 mg/mL | GHK-Cu 250 · BPC-157 50 · TB-500 50 | GHK-Cu 2,500 · BPC-157 500 · TB-500 500 |
| GLOW 70 mg + 3 mL | 23.33 mg/mL | GHK-Cu 166.7 · BPC-157 33.3 · TB-500 33.3 | GHK-Cu 1,666.7 · BPC-157 333.3 · TB-500 333.3 |
| Wolverine 20 mg + 2 mL | 10 mg/mL | BPC-157 50 · TB-500 50 | BPC-157 500 · TB-500 500 |
| CJC-1295 (No DAC) + ipamorelin 10 mg + 2 mL | 5 mg/mL | CJC-1295 25 · Ipamorelin 25 | CJC-1295 250 · Ipamorelin 250 |
Composition of the GLOW vial and each part's share:
| Component | mg in vial | Share of vial mass | Ratio to GHK-Cu |
|---|---|---|---|
| GHK-Cu | 50 | 71.4% | 1 |
| BPC-157 | 10 | 14.3% | 0.2 |
| TB-500 | 10 | 14.3% | 0.2 |
The share column explains a common surprise: in GLOW, GHK-Cu is about 71% of the vial's mass, so most of every draw is GHK-Cu. Compound background is in the dossiers for GLOW, Wolverine and CJC-1295 + ipamorelin.
What happens when you aim at one compound?
If you fix an amount for one component, the others follow automatically. For a GLOW vial with 2 mL, aiming at a set amount of GHK-Cu carries BPC-157 and TB-500 along at one fifth of it each (input amounts, arithmetic only):
| Target GHK-Cu (input) | Units at +2 mL | BPC-157 carried along | TB-500 carried along |
|---|---|---|---|
| 500 mcg | 2 | 100 mcg | 100 mcg |
| 1,000 mcg | 4 | 200 mcg | 200 mcg |
| 2,000 mcg | 8 | 400 mcg | 400 mcg |
The calculator's "Target of A" field does this for any blend. If the amount carried along for B or C does not suit the work, the only solution is a different product — single-compound vials, measured separately — not a different water volume, which changes all components equally.
Target mode is also the fastest way to compare a blend against single vials. Set the amount of the main component you are interested in and look at what the others come to; if those carried amounts are unwanted, the blend is the wrong format for that work.
How does added water change a blend?
More water lowers every component's per-unit figure by the same factor and leaves the ratio untouched. GLOW at 3 mL holds 166.7 mcg GHK-Cu per unit instead of 250; BPC-157 and TB-500 fall from 50 to 33.3 mcg. Choosing the volume is therefore the same readability decision as for a single compound: pick the one that makes your draws land on clear marks. The vial must also hold the volume with room to spare; a 70 mg blend at 1 mL becomes a very concentrated solution.
One more reason to choose the volume carefully: with three components, the smallest one sets the readability limit. In GLOW, BPC-157 and TB-500 are a fifth of GHK-Cu, so a draw that is easy to read for GHK-Cu may leave the smaller parts at amounts you would want to know precisely. The calculator shows all three side by side so the trade-off is visible before reconstitution.
Single vials or a blend: which tool fits?
| Blend vial | Single-compound vials | |
|---|---|---|
| Ratio between compounds | Fixed by the manufacturer | Set independently |
| Arithmetic | Per component, this calculator | One concentration each, reconstitution calculator |
| Measurements per use | One | One per compound |
| Flexibility | Low | High |
| Documentation | One COA should list each component | One COA per vial |
For a blend, the certificate of analysis should identify each component, not just the total mass; see how to read a COA. A batch document is available on request with each order.
Blends in the Vietnam catalogue
GLOW, Wolverine, KLOW and CJC-1295 + ipamorelin are each listed in a single format with dated VND prices in the price index; bacteriostatic water is sold separately. The total is confirmed in writing before payment, and delivery takes about 30 minutes in Da Nang and 1–2 days elsewhere in Vietnam. These are research materials; the calculator handles proportions only.
How many draws does a blend vial give?
Draws depend only on the water volume and the draw size, not on how many components the vial contains (calculated):
| Draw size | +2 mL water | +3 mL water |
|---|---|---|
| 5 units | 40 | 60 |
| 10 units | 20 | 30 |
| 20 units | 10 | 15 |
| 25 units | 8 | 12 |
| 50 units | 4 | 6 |
The last partial draw is usually unrecoverable from the vial's bottom, so in practice the count is slightly lower than the arithmetic. Planning around whole draws avoids reconstituting a second vial early.
Common mistakes with blended vials
Peptide blends: price in Vietnam
Blend formats and VND prices from the supplier's dated catalogue.
| Compound | Format | Price | |
|---|---|---|---|
| Glow | 70 mg | 2 500 000 ₫ | Buy → |
| BPC-157 + TB-500 (Wolverine) | 20 mg blend | 2 500 000 ₫ | Buy → |
| KLOW | 80 mg | 2 700 000 ₫ | Buy → |
| CJC-1295 (No DAC) + Ipamorelin | 10 mg blend | 1 800 000 ₫ | Buy → |
Frequently asked questions
What does a peptide blend calculator compute?
Each component's concentration and mcg per unit, the amount of each in a draw, draws per vial and the units for a target of one component.
Can I change one compound without changing the others?
No. Every draw carries all components in the vial's fixed ratio.
How do I find a blend's ratio?
Divide each component's mg by the first one's. GLOW: 50 : 10 : 10 = 1 : 0.2 : 0.2.
Does more water change the ratio?
No. It lowers every component's per-unit amount equally.
How many draws does a vial give?
Water mL × 100 ÷ units per draw. 2 mL and 10-unit draws give 20.
How much GHK-Cu is in 10 units of GLOW at 2 mL?
2,500 mcg, with 500 mcg each of BPC-157 and TB-500.
Why not use the total concentration?
It describes all components together. For one component, use its own mg ÷ mL.
Sources and data date
- Arithmetic only: concentration = mass ÷ volume; U-100 syringe = 100 units per mL, U-40 = 40 units per mL. How we select sources: editorial standards.
- Blend compositions as listed in the VietPeptide catalogue: GLOW = GHK-Cu 50 mg + BPC-157 10 mg + TB-500 10 mg; Wolverine = BPC-157 10 mg + TB-500 10 mg; CJC-1295 (No DAC) 5 mg + ipamorelin 5 mg.
Keep reading
Research materials are supplied by VietPeptide, our partner in Da Nang: the total is confirmed in writing before payment, delivery takes about 30 minutes in Da Nang and 1–2 days elsewhere in Vietnam.